our products
our products
information_top

Call us at:

(818)591-3030

USA

Click here to send us an email
tel_section

Diagnostic Automation Question & AnswerDiagnostic Automation Question & Answer Diagnostic Automation Articles Diagnostic Automation videos



Influenza A IgG ELISA kit

Name

Influenza A IgG ELISA Test

Full name

Human Influenza A IgG ELISA Test Kit

Category Name Infectious Disease ELISA kits
Test 96
Method ELISA method: Enzyme Linked Immunosorbent Assay
Principle ELISA principle- Indirect; Antigen Coated Plate
Detection Range Qualitative elisa assay- Positive, Negative and Cut-off
Sample 100ul
Specificity 88%
Sensitivity 100%
Total Time 110min
Shelf Life 12 Months from the manufacturing date

Item #:                    5105-8   Quantity:               

Influenza A IgG ELISA kit


Influenza A IgG ELISA kit

callback phone number email us


Influenza A IgG ELISA kit description:




Diagnostic Automation Inc. Influenza A IgG Antibody ELISA (EIA) Test Kit has been designed for the detection and quantitative determination of specific IgG antibodies against Influenza A in human serum and plasma. Further applications in other body fluids are possible and can be requested from the Technical Service of Diagnostic Automation Inc.




Materials Provided with Influenza A IgG ELISA Kit:
1. Influenza A IgG EIA Kit Microtiter Strips: 12 strips with 8 breakable wells,
coated with an Influenza A antigen (Current vaccine, strains Beijing and Sydney)
2. Influenza A IgG ELISA Test Kit Calibrator A (Negative Control)
contains no IgG antibodies against Influenza A
3. Influenza A IgG ELISA Test Kit Calibrator B (Cut-Off Standard)
contains a low concentration of IgG antibodies against Influenza A
4. Influenza A IgG ELISA Kit Calibrator C (Weak Positive Control)
contains a medium concentration of IgG antibodies against Influenza A
5. Influenza A IgG ELISA Kit Calibrator D (Positive Control)
contains a high concentration of IgG antibodies against Influenza A
6. Influenza A IgG Eia test Enzyme Conjugate
anti-human-IgG-HRP (rabbit), in protein-containing buffer solution
7. Influenza A IgG Eia test Kit Substrate, 15 ml
8. Stop Solution
9. Sample Diluent
10. Washing Buffer
11. Plastic Foils
12. Plastic Bag

Materials & Instrumentations required not included:
1. Bidistilled water
2. Precision pipettes, 5-100 & 500 ul
3. EIA Kit Microplate Washer
4. EIA Kit Microplate Reader at 450





Influenza A IgG ELISA (EIA) Background Information:
The influenza infection is an acute feverish virus infection, which principally leads to an illness of the respiratory tract and appears as an epidemic or pandemic. The infection mostly results from a droplet infection. The virus spreads from the mucous membrane of the upper respiratory to the whole bronchial tract. There the virus and its toxin can lead to a serious inflammation of the bronchial mucosa and a damage of the vessels. After incubation time of 1 to 3 days the symptoms appear, followed by a fast increase of temperature, often accompanied by shivering, catarrhal leading symptom, a rhinitis and conjunctivitis. The Influenza viruses form a virus group with principally similar morphological, chemical and biological features. The types A, B and C were defined, from which many other variants are known. The determination of the Influenza type (A, B, and C) gives both the clinician and epidemiologist important indications for further actions. During Influenza A epidemic, the epidemiological importance and derived measures for the protection of the individual and population primarily stand in the foreground together with the severity of the clinical symptoms.




Influenza A IgG ELISA (EIA) Test Principle:
The Diagnostic Automation Influenza A IgG antibody test kit is based on the principle of the enzyme immunoassay (EIA). Influenza A antigen is bound on the surface of the microtiter strips. Diluted patient serum or ready-to-use standards are pipetted into the wells of the microtiter plate. A binding between the IgG antibodies of the serum and the immobilized Influenza A antigen takes place. After one hour incubation at room temperature, the plate is rinsed with diluted wash solution, in order to remove unbound material. Then ready-to-use anti-human-IgG peroxidase conjugate is added and incubated for 30 minutes. After a further washing step, the substrate (TMB) solution is pipetted and incubated for 20 minutes, inducing the development of a blue dye in the wells. The color development is terminated by the addition of a stop solution, which changes the color from blue to yellow. The resulting dye is measured spectrophotometrically at the wavelength of 450 nm. The concentration of the IgG antibodies is directly proportional to the intensity of the color.




Influenza A IgG ELISA test kit Qualitative Evaluation
The calculated absorptions for the patient sera are compared with the value for the cutoff standard. If the value of the sample is higher, there is a positive result. For a value below the cut-off standard, there is a negative result. It is recommended to define a range of +/- 20 % around the value of the cut-off as a grey zone. In such a case the repetition of the test with the same serum or with a new sample of the same patient, taken after 2-4 weeks, is recommended. Both samples should be measured in parallel in the same run. The positive control must show at least the double absorption compared with the cut-off standard.






Influenza A IgG Related ELISA kits:


Influenza A IgA ELISA Kit

http://www.rapidtest.com/index.php?i=Influenza-A-IgA-ELISA-kit&id=93&cat=16

Influenza A IgM ELISA Kit

http://www.rapidtest.com/index.php?i=Influenza-A-IgM-ELISA-kit&id=95&cat=16



Diagnostic Automation Inc. also provides other Infectious Disease ELISA Kits:

http://www.rapidtest.com/index.php?product=Infectious-Disease-ELISA-kits&cat=16


For more information about these Kits or Rapid Tests, IFA Kits, CLIA Test Kits, or Serology tests, please see our website home page, or contact our Customer Service Representative at 818-591-3030.





Product Note:

Our Influenza A IgG Antibody ELISA Test Kit has been designed for the the detection and the quantitative determination of specific IgG antibodies against Influenza A in serum and plasma. 

Got error 28 from storage engine