Mycobacterium Tuberculosis IgA (TB) ELISA Test

Name

Mycobacterium Tuberculosis IgA (TB) ELISA Kit

Full name

Human Mycobacterium Tuberculosis IgA (TB) ELISA Test kit

Category Name Infectious Disease ELISA kits
Test 96
Method ELISA: Enzyme Linked Immunosorbent Assay
Principle Indirect ELISA: Antigen Coated Plate
Detection Range Qualitative: Positve & Negative Control
Sample 10uL
Specificity 99%
Sensitivity 100%
Total Time ~50min
Shelf Life 12-14 months

Item #:                    5110-8   Quantity:               

Mycobacterium Tuberculosis IgA (TB) ELISA Test


Mycobacterium Tuberculosis IgA (TB) ELISA Test

callback phone number email us


Mycobacterium Tuberculosis IgA (TB) ELISA Test description:




Diagnostic Automation Inc. Mycobacterium Tuberculosis IgA ELISA Kit is an Enzyme immunoassay (EIA) for the detection and quantitative determination of human IgA antibodies against Mycobacterium Tuberculosis in human serum and plasma. Further applications of this elisa kit in other body fluids are possible and can be requested from our Technical Service at 818-591-3030.





Materials Provided with Mycobacterium Tuberculosis IgA ELISA Test Kit:
1. Mycobacterium Tuberculosis IgA EIA Kit Microtiter Strips: wells coated with a
M. tuberculosis antigen mixture (recombinant Mycobacterium tuberculosis antigens
2. Mycobacterium Tuberculosis IgA ELISA Kit Calibrator A (Negative Control)
3. Mycobacterium Tuberculosis IgA ELISA Kit Calibrator B (Cut-Off Standard)
4. Mycobacterium Tuberculosis IgA ELISA Kit Calibrator C (Weak Positive Control)
5. Mycobacterium Tuberculosis IgA ELISA Test Kit Calibrator D (Positive Control)
6. Influenza A IgA Eia Test Enzyme Conjugateanti-human-IgA-HRP (rabbit
7. Mycobacterium Tuberculosis IgA Eia Test Kit Substrate
8. Stop Solution
9. Sample Diluent
10. Washing Buffer
11. Plastic Foils
12. Plastic Bag

Materials & Instrumentations required not included:
1. Reagent tubes for the serum dilution
2. Bidistilled water
3. Precision pipettes
4. EIA Kit Microplate Washer
5. EIA Kit Microplate Reader at 450 nm





Mycobacterium Tuberculosis IgA ELISA (EIA) Kit Background Information
Mycobacterioses (tuberculosis, leprosy, atypical mycobacterioses, paratuberculosis, and perhaps
Crohn's Disease) are the infectious diseases of men and animals with the largest diffusion on earth. The infectious agents of tuberculosis are acid-resistant rod-like formed bacteria of the family Mycobacteriaceae, genus Mycobacterium. The germ was detected by Robert Koch in 1882. Owing to the very high infectious power of pathogenic mycobacteria, early diagnosis is essential to prevent spreading of the disease. Convergence of various approaches is necessary to control the mycobacterioses, immune reactions, and bacterial shedding during the diseases. The illness is normally transferred by droplets of saliva from infected persons. This ELISA test kit for the determination of IgA antibodies uses a cocktail of highly pure proteins in order to determine an immune response against the bacteria in human serum. A fresh or chronically active infection can be diagnosed by IgG and IgM tests, which are also available.




Mycobacterium Tuberculosis IgA ELISA (EIA) Test Principle
Mycobacterium tuberculosis antigen is bound on the surface of the microtiter strips. Diluted patient serum or ready-to-use standards are pipetted into the wells of the microtiter plate. A binding between the IgA antibodies of the serum and the immobilized Mycobacterium tuberculosis antigen takes place. After one hour incubation at room temperature, the plate is rinsed with diluted wash solution, in order to remove unbound material. Then ready-to-use anti-human-IgA peroxidase conjugate is added and incubated for 30 minutes. After a further washing step, the substrate (TMB) solution is pipetted and incubated for 20 minutes, inducing the development of a blue dye in the wells. The color development is terminated by the addition of a stop solution, which changes the color from blue to yellow. The resulting dye is measured spectrophotometrically at the wavelength of 450 nm. The concentration of IgA antibodies is directly proportional to the intensity of the color.




Mycobacterium Tuberculosis IgA ELISA Performance Characteristics
Intra-Assay Precision 7.9 %
Inter-Assay Precision 7.4 %
Inter-Lot-Precision 5.7 8.9 %
Analytical Sensitivity 1.34 U/ml
Recovery 87 96 %
Linearity 78 111 %
Cross-Reactivity No cross-reactivity to Helicobacter pylori and Bordetella pertussis
Interferences No interferences to bilirubin up to 0.3 mg/mL, hemoglobin up to 8.0 mg/ml & triglycerides up to 5.0 mg/ml




Precautions on Mycobacterium Tuberculosis IgA EIA Test Kit
All sera and plasma or buffers based upon, have been tested respective to HBsAg, HIV and HCV with recognized methods and were found negative. Nevertheless precautions like the use of latex gloves have to be taken.



Mycobacterium Tuberculosis IgA ELISA Related Kits:

Mycobacterium Tuberculosis IgG ELISA Kit

http://www.rapidtest.com/index.php?i=-Mycobacterium-Tuberculosis-IgG-(TB)-IgG-ELISA-kit&id=100&cat=16

Mycobacterium Tuberculosis IgM ELISA Kit

http://www.rapidtest.com/index.php?i=Mycobacterium-Tuberculosis-(TB)-IgM-ELISA-kit&id=101&cat=16



Diagnostic Automation Inc. also provides other Test Kits:

http://www.rapidtest.com/index.php?product=Rapid-Tests


For more information about ELISA Kits, Rapid Tests, CLIA tests, or IFA Tests, please contact our Customer Service Representatives at 818-591-3030.







Product Note:

Our TB IgA have high sensitivity and specificity.

Got error 28 from storage engine