our products
our products
information_top

Call us at:

(818)591-3030

USA

Click here to send us an email
tel_section

Diagnostic Automation Question & AnswerDiagnostic Automation Question & Answer Diagnostic Automation Articles Diagnostic Automation videos



Urine Reagent Strip (Blood - Ketone - Glucose - Protein - pH - Bilirubin)

Name

Urine Reagent Strip (Blood - Ketone - Glucose - Protein - pH - Bilirubin)

Category Name Urine Reagent Strips tests
Test 100 strips

Item #:                    URS-6   Quantity:               

Urine Reagent Strip (Blood - Ketone - Glucose - Protein - pH - Bilirubin)

URS-1 to 10 MSDS (2017-1-11).pdf

Urine Reagent Strip (Blood - Ketone - Glucose - Protein - pH - Bilirubin)

callback phone number email us


Urine Reagent Strip (Blood - Ketone - Glucose - Protein - pH - Bilirubin) description:




Los Angeles-based Diagnostic Automation/Cortez Diagnostics, Inc. offers a Urine Reagent Strip (Blood-Ketone-Glucose-Protein-pH-Bilirubin) Rapid Test for the semi-quantitative and qualitative detection of Blood, Ketone, Glucose, Protein, pH, and Bilirubin in urine.  The Urine Reagent Strip for Urinalysis is for in-vitro diagnostic use only.

The Urine Reagent Strip (Blood) Rapid Test is based on the pseudoperoxidase action of hemoglobin and erythrocytes which catalyzes the reaction of 3,3', 5, 5' -tetramethyl-benzidine and buffered organic peroxide.   This test has a sensitivity to free hemoglobin of 0.015 mg/dl, or 5-10 intact red blood cells/uL urine.

The Urine Reagent Strip (Ketone) Rapid Test is based on the reaction of acetoacetic acid with sodium nitroprusside in a strongly basic medium.  The sensitivity of the test provides semi-quantitative results and reacts with acetoacetic acid in urine.  This test does not react with beta-hydroxybutyric acid or acetone.  The reagent area detects as little as 5-10 mg/dl acetoacetic acid in urine.

The Urine Reagent Strip (Glucose) Rapid Test is based on a double sequential enzyme reaction.    The test area is specific for glucose; no substance excreted in urine other than glucose is known to give a positive result.  Approximately 100 mg/dl glucose in urine is detectable.

The Urine Reagent Strip (Protein) Rapid Test is based on the protein error-of-indicator principle.   The test area is more sensitive to albumin than to globulin, hemoglobin, Bence-Jones proteins, and mucoprotein; a negative result does not rule out the presence of these other proteins.  The test area is sensitive to 15 mg/dl albumin. 

The Urine Reagent Strip (pH) Rapid Test
is based on the well known double pH indicator method, where bromothymol blue and methyl red give distinguishable colors over the pH range of 5-9.  The test area permits quantitative differentiation of pH values to one unit within the range of 5-9.  pH reading is not affected by variation in the urinary buffer concentration.

The Urine Reagent Strip (Bilirubin) Rapid Test is based on the coupling of bilirubin with a diazotized dichloroaniline in a strongly acid medium. The test has a sensitivity of 0.4-0.8 mg/dl in bilirubin in urine.

Notable features of the Urine Reagent Test Strip (Blood-Ketone-Glucose-Protein-pH-Bilirubin) Rapid Test:

    •    reliable and inexpensive
    •    easy-to-understand directions
    •    clear preparation and storage procedures
    •    simple specimen collection directions
    •    safe and convenient packaging
    •    rapid and accurate test results

See Urine Reagent Strips for Urinalysis (Blood-Ketone-Glucose-Protein-pH-Bilirubin) Product Insert for more specific details on preparation, procedures, storage, quality control, and interpretation of test results.

Diagnostic Automation/Cortez Diagnostics, Inc.
also offers several other Urine Diagnostic Reagent Test Strips.   For more information about these Urine Reagent Diagnostic Rapid Test Strips, or any other Rapid Test, ELISA Test, CLIA Test kits, Serology test, or IFA Test kits, please contact our Customer Service Representatives at 818-591-3030.